XLPE INSULATED PVC SHEATHED UNARMOURED CABLES


DOUBLE XLPE INSULATED SINGLE CORE CABLE


XLPE Insulated and PVC Sheathed.
Voltage Rating: 600/1000V.
Outer Sheath: Black.
Manufactured as per BS.5467/1989.

Double Insulated XLPE CABLE

Nominal Cross Sectional Area

Wire Construction

Nominal Overall Diameter

Nominal Weight

mm²

mm

mm

kg/Km

50

1.13

14.7

560

70

1.38

16.5

787

95

1.78

19.0

1052

120

2.55

20.6

1447

150

3.12

22.7

1649

185

4.05

25.2

2026

240

5.10

28.2

2659

300

6.42

31.4

3253

600/1000 V - COPPER CONDUCTOR XLPE INSULATED PVC SHEATHED UNARMOURED CABLES (CU/XLPE/PVC)


DOUBLE XLPE INSULATED SINGLE CORE CABLE

Circular solid conductor (Class 1.)
All other conductors circular stranded or circular stranded compacted (Class 2).
Cables upto and including 35 Sqmm conform to IEC 502 - 1994.
All other cables conform generally to BS 5467 - 1997 and IEC 502 - 1994.



SINGLE CORE

Nominal Area of Conductor

Thickness of Insulation 

Thickness of Outer Sheath

Approx. Overall Diameter

Approx. Cable Weight

Sq. mm

mm

mm

mm

Kg/Km

CABLES

1.5*

0.7

1.4

6.5

57

1.5

0.7

1.4

6.7

60

2.5*

0.7

1.4

6.9

69

2.5

0.7

1.4

7.1

72

4

0.7

1.4

7.6

90

6

0.7

1.4

8.2

115

10

0.7

1.4

8.9

160

16

0.7

1.4

10.0

220

25

0.9

1.4

11.6

320

35

0.9

1.4

12.7

420

50

1.0

1.4

14.0

550

70

1.1

1.4

15.8

760

95

1.1

1.5

17.9

1030

120

1.2

1.5

19.6

1270

150

1.4

1.6

21.6

1580

185

1.6

1.6

23.6

1920

240

1.7

1.7

26.5

2470

TWO / THREE / FOUR CORE (CU/XLPE/PVC)

Conductor

2 Core

Norminal
cross-sectional
area

Diameter

Thickness
of
insulation

Thickness
of Sheath

Approx.
overal diameter

Approx
.Weight
(kg/km)

mm2

mm

mm

mm

mm1

kg/km

2.5

2.01

0.7

1.8

11.5

155

4

2.55

0.7

1.8

12.5

195

6

3.12

0.7

1.8

13.5

255

10

4.05

0.7

1.8

15.5

360

16

4.7

0.7

1.8

17

490

25

5.9

0.9

1.8

20

720

35

7.0

0.9

1.8

22

960

50

8.0

1.0

1.8

25

1290

70

9.7

1.1

1.8

29

1750

95

11.4

1.1

1.9

32

2310

120

12.8

1.2

2.0

36

2880

150

14.3

1.4

2.2

40

3610

185

15.8

1.6

2.3

44

4410

240

18.4

1.7

2.5

50

5690

3 core

4 core

Thickness of Sheath

Approx.
overal diameter

Approx
.Weight

Thickness of Sheath

Approx.
overal diameter

Approx
.Weight

mm

mm1

kg/km

mm

mm1

kg/km

1.8

12.0

190

1.8

13.0

230

1.8

13.5

240

1.8

14.0

305

1.8

15.0

320

1.8

16.0

405

1.8

16.5

465

1.8

18.0

590

1.8

18.5

650

1.8

20

835

1.8

22

965

1.8

24

1250

1.8

24

1290

1.8

26

1670

1.8

27

1770

1.9

30

2305

1.9

31

2440

2.0

34

3190

2.0

35

3240

2.1

39

4230

2.1

39

4050

2.3

43

5320

2.3

43

5050

2.4

49

6610

2.4

48

6200

2.6

53

8140

2.6

53

7990

2.8

61

10520

FOUR CORE WITH REDUCED NEUTRAL (CU/XLPE/PVC)

Nominal Area of Conductor

Maximum Conductor Resistance at 20°C

Thickness of Insulation

Thickness of Outer Sheath

Approx. Overall Diameter

Approx. Cable Weight

Phase

Neutral

Phase

Neutral

Phase

Neutral

Sqmm

Ohm/Km

mm

mm

mm

Kg/Km

CABLES

25

16

0.727

1.15

0.9

0.7

1.8

22.0

1090

35

16

0.524

1.15

0.9

0.7

1.8

25.4

1410

50

25

0.387

0.727

1.0

0.9

1.8

28.3

1890

70

35

0.268

0.524

1.1

0.9

1.9

31.8

2610

95

50

0.193

0.387

1.1

1.0

2.0

36.1

3520

120

70

0.153

0.268

1.2

1.1

2.2

39.7

4480

150

70

0.124

0.268

1.4

1.1

2.3

44.6

5440

185

95

0.0991

0.193

1.6

1.1

2.4

49.3

6760

240

120

0.0754

0.153

1.7

1.2

2.6

54.4

8631

300

150

0.0601

0.124

1.8

1.4

2.8

60.2

10810

300

185

0.0601

0.0991

1.8

1.6

2.9

60.4

11120

Top